 | Mean Well| Meanwell | Switching Power Supply| Single, Dual, Triple And Quad Output
|  |
 |
|  |  |  |
|  |  | | |  | |  | Dimension: 99*97*36mm (L*W*H)Universal AC input / full rangeProtections: SC / OL / OVDC adjustment range: ±10% rated output voltageApprovals: UL / TUV / CECooling by free air convection100% full load burn-in test2 years warrantyAC input voltage range: 85 - 264VAC; 120 - 370 VDCDC adjustment range: ±10% rated output voltage
| Model # | Output | Tol. | R&N | Effi. |
|---|
| S-25-5 | 5V, 0~5A | ±2% | 50mV | 72% | | S-25-12 | 12V, 0~2.1A | ±1% | 100mV | 76% | | S-25-15 | 15V, 0~1.7A | ±1% | 100mV | 77% | | S-25-24 | 24V, 0~1.1A | ±1% | 100mV | 80% |
| | Price: $32.45 | |  | |
|  |  | | |  | |  |
Dimension: 129*98*38mm (L*W*H)) Universal AC input / full rangeProtections: SC / OL / OVDC adjustment range: ±10% rated output voltageApprovals: UL / CUL / TUV / CB / CECooling by free air convection100% full load burn-in test2 years warrantyAC input voltage range: 85-264VAC; 120-370 VDCDC adjustment range: ±10% rated output voltage
| Model # | Output | Tol. | R&N | Effi. |
|---|
| S-40-5 | 5V, 0~8A | ±2% | 75mV | 72% | | S-40-12 | 12V, 0~3.5A | ±1% | 100mV | 76% | | S-40-15 | 15V, 0~2.8A | ±1% | 100mV | 76% | | S-40-24 | 24V, 0~1.8A | ±1% | 100mV | 78% |
| | Price: $37.90 | |  | |
|  |  | | |  | |  | Dimensions: 159*97*38mm (L*W*H))
AC input range selectable by switchProtections: SC / OL / OVFixed switching frequency @ 25KHzApprovals: UL / CUL / TUV / CB / CECooling by free air convection100% full load burn-in test2 years warrantyAC input voltage range: 85 ~ 264VAC; 120 ~ 370VDCAC Inrush Current: Cold start, 30A @ 115VAC, 60A @ 230VACDC Adjustment Range: ±10% rated output voltage
| Model # | Output (VDC) | Tol. | R&N (mVp-p) | Effi. |
|---|
| S-60-5 | 5V, 0~12A | ±2% | 120mV | 73% | | S-60-12 | 12V, 0~5A | ±1% | 120mV | 76% | | S-60-15 | 15V, 0~4A | ±1% | 150mV | 77% | | S-60-24 | 24V, 0~2.5A | ±1% | 150mV | 79% |
| | Price: $42.35 | |  | |
|  |  | | |  | |  | Dimensions: 199*98*38mm (L*W*H)
AC input range selectable by switchProtections: SC / OL / OVFixed switching frequency at 83KHzApprovals: UL / CUL / TUV / CB / CECooling by free air convection100% full load burn-in test2 years warrantyAC input voltage range: 88 - 132VAC; 176-264VDC selectable by switchDC adjustment range: ±10% rated output voltage
| Model # | Output | Tol. | R&N | Effi. |
|---|
| S-100F-5 | 5V, 0~20A | ±2% | 100mV | 76% | | S-100F-7.5 | 7.5V, 0~13.5A | ±1% | 125mV | 78% | | S-100F-12 | 12V, 0~8.5A | ±1% | 125mV | 80% | | S-100F-15 | 15V, 0~6.7A | ±1% | 125mV | 81% | | S-100F-24 | 24V, 0~4.5A | ±1% | 150mV | 83% | | S-100F-48 | 48V, 0~2.2A | ±1% | 150mV | 84% |
| | Price: $49.45 | |  | |
|  |  | | |  | |  | Dimensions: 199*110*50mm (L*W*H)
AC input range selectable by switchProtections: SC / OL / OVFixed switching frequency at 25KHzApprovals: UL / CUL / TUV / CB / CECooling by free air convection100% full load burn-in test2 years warrantyAC input voltage range: 88 - 132VAC; 176-264VDC selectable by switchDC adjustment range: ±10% rated output voltage
| Model # | Output | Tol. | R&N | Effi. |
|---|
| S-150-5 | 5V, 0~30A | ±2% | 150mV | 78% | | S-150-7.5 | 7.5V, 0~20A | ±1% | 150mV | 80% | | S-150-9 | 9V, 0~16.7A | ±1% | 180mV | 80% | | S-150-12 | 12V, 0~12.5A | ±1% | 180mV | 82% | | S-150-13.5 | 13.5V, 0~11.2A | ±1% | 180mV | 83% | | S-150-15 | 15V, 0~10A | ±1% | 180mV | 84% | | S-150-24 | 24V, 0~6.5A | ±1% | 240mV | 85% | | S-150-27 | 27V, 0~5.6A | ±1% | 240mV | 86% | | S-150-48 | 48V, 0~3.2A | ±1% | 240mV | 87% |
| | Price: $55.45 | |  | |
|  |  | | |  | |  | Dimensions: 215x 115x 50(L*W*H)
AC input range selectable by switchProtections: SC / OL / OV / OT100% full load burn-in testFixed switching frequency at 90KHzLow costHigh reliability2 years warrantyAC input voltage range: 88 ~ 132VAC / 176 ~ 264VAC by switchAC inrush current: Cold start, 35A/115VAC, 50A/230VACDC Adjustment Range: ±10% rated output voltage>Safety standards: UL60950-1 Approved
| Model # | Output (VDC) | Tol. | R&N (mVp-p) | Effi. |
|---|
| S-210-5 | 5V, 0~40A | ±2% | 80mV | 79% | | S-210-7.5 | 7.5V, 0~27A | ±2% | 100mV | 82% | | S-210-12 | 12V, 0~17A | ±1% | 120mV | 83% | | S-210-13.5 | 13.5V, 0~15A | ±1% | 120mV | 84% | | S-210-15 | 15V, 0~14A | ±1% | 120mV | 85% | | S-210-24 | 24V, 0~8.8A | ±1% | 200mV | 87% | | S-210-27 | 27V, 0~7.8A | ±1% | 200mV | 87% | | S-210-48 | 48V, 0~4.4A | ±1% | 200mV | 87% |
| | Price: $70.95 | |  | |
|  |  | | |  | |  | Dimensions: 190*93*65mm (L*W*H)
AC input range auto sensingProtections: SC / OL / OVFixed switching frequency at 75KHzApprovals: UL / CUL / TUV / CB / CEForce air cooling by built-in DC fanColling fan ON/OFF auto control100% full load burn-in test2 years warrantyAC input voltage range: 88-132VAC; 176-264VDC selectable by switchDC adjustment range: ±10% rated output voltage
| Model # | Output | Tol. | R&N | Effi. |
|---|
| S-240-5 | 5V, 0~40A | ±2% | 150mV | 78% | | S-240-7.5 | 7.5V, 0~30A | ±2% | 200mV | 80% | | S-240-12 | 12V, 0~18A | ±1% | 150mV | 82% | | S-240-15 | 15V, 0~15A | ±1% | 150mV | 83% | | S-240-24 | 24V, 0~10A | ±1% | 180mV | 84% | | S-240-30 | 30V, 0~8A | ±1% | 180mV | 85% | | S-240-48 | 48V, 0~5A | ±1% | 240mV | 87% |
| | Price: $108.20 | |  | |
|  |  | | |  | |  | Dimensions: 150*140*86mm (L*W*H)
AC input range selectable by switchProtections: SC / OL / OVFixed switching frequency at 60KHzApprovals: ULForce air colling by built-in DC fan100% full load burn-in testLow cost, High reliability2 years warrantyAC input voltage range: 90 - 132VAC; 176 - 264VDC selectable by switchAC inrush current: Cold start, 50A at 230VACDC adjustment range: ±10% rated output voltage
<| Model # | Output | Tol. | R&N | Effi. |
|---|
| S-250-5 | 5V, 0~40A | ±2% | 80mV | 74% | | S-250-12 | 12V, 0~18A | ±1% | 120mV | 79% | | S-250-15 | 15V, 0~15A | ±1% | 120mV | 80% | | S-250-24 | 24V, 0~10A | ±1% | 120mV | 81.5% | | S-250-27 | 27V, 0~9A | ±1% | 150mV | 82% | | S-250-48 | 48V, 0~5.2A | ±1% | 200mV | 82% |
| | Price: $63.80 | |  | |
|  |  | | |  | |  | Dimensions: 215*115*50mm (L*W*H)
AC input range selectable by switchProtections: SC / OL / OVFixed switching frequency at 90KHzApprovals: UL / CULForce air colling by built-in DC fanCooling fan ON/OFF auto control100% full load burn-in test2 years warrantyAC input voltage range: 88 - 132VAC; 176 - 264VDC selectable by switchAC inrush current: Cold start, 20A at 115VAC, 40A at 230VACDC adjustment range: ±10% rated output voltage
| Model # | Output | Tol. | R&N | Effi. |
|---|
| S-320-5 | 5V, 0~50A | ±2% | 150mV | 77% | | S-320-7.5 | 7.5V, 0~36A | ±2% | 150mV | 80% | | S-320-12 | 12V, 0~25A | ±1% | 150mV | 82% | | S-320-13.5 | 13.5V, 0~22A | ±1% | 150mV | 83% | | S-320-15 | 15V, 0~20A | ±1% | 150mV | 84% | | S-320-24 | 24V, 0~12.5A | ±1% | 150mV | 86% | | S-320-27 | 27V, 0~11A | ±1% | 200mV | 86% | | S-320-48 | 48V, 0~6.5A | ±1% | 240mV | 87% |
| | Price: $98.80 | |  | |
|  | | *
Universal Application, Low Cost, In Stock, Order Online, Same Day Shipment World Wide!
Mean Well| Meanwell | Switching Power Suppllies are widely used all over the world. Mean Well power supplies will meet your needs for AC dc and DC DC power requirements.
MeanWell power supply means reliable power supplies. The high reliability and low cost associated with MeanWell AC DC Power Supplies define why hospitals and other medical establishments across the United States depend upon Mean Well as their power provider. Whether your power consuming needs are for avionics, medicine, computers or other purposes Power Factor will provide you with the highest quality Mean Well power supply at the lowest price possible.
| | |
| |
|